Medium voltage power cable used to transmit rated voltage from 1kV to 36kV, specified in Part 1 of TCVN 5935-1 : 2013 (IEC 60502-1:2009): Cable for rated voltage equal to 1 kV ( Um = 1,2 kV) and 3 kV (Um = 3.6 kV) and Part 2 TCVN 5935-2:2013 (IEC 60502-2:2005): Cables for rated voltages from 6 kV (Um = 7). ,2 kV) to 30 kV (Um = 36 kV).
…
Regulations on structure of medium voltage cables
The content is specified as follows:
1. TCVN 5935-1:2013 – Part 1
Cables for rated voltages of 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 kV).
- The rated voltage Uo/U(Um) of the cables considered in this standard is 1.8/3 (3.6) kV.
- Insulating compound
- PVC thermoplastic;
- Cross-linked insulating compound: Ethylene propylene rubber or the like (EPR), molecular rubber or high hardness ethylene propylene rubber (HEPR), Cross-linked polyethylene (XLPE).
- The maximum conductor temperature in normal operation is 70 degrees C (if PVC insulation) and 90 degrees C (if XLPE insulation).
- Conductors: Must be class 1 (1 solid conductor) or class 2 (braided conductor) (according to IEC 60228:2004) of annealed copper/coated with aluminum or aluminum alloy;
- Regulations on the minimum thickness of each insulating compound on each product classified according to the following nominal cross-sections: 1.5 and 2.5mm2, 4 and 6mm2, 10 and 16mm2, 25 and 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2…
- Thickness of extruded, wound inner coating (0.4mm);
- Maximum resistance: The measured resistance value must be corrected to a temperature of 20 degrees C and 1 km of length according to the formula and coefficient stated in IEC 60228.
2. TCVN 5935-2:2013 – Part 2
Power cables for rated voltages from 6 kV (Um = 7.2 kV) to 30 kV (Um = 36 kV).
- The rated voltage Uo/U(Um) of the cables considered in this standard is as follows: Uo/U(Um) = 3.6/6 (7.2) – 6/10 (12) – 8.7 /15 (17.5) – 12/20 (24) – 18/10 (36) kV.
- Insulating compound
- PVC/B for cable lines with rated voltage Uo/U = 3.6/6 kV;
- Thermosetting plastic: Ethylene propylene rubber or similar (EPR), High hardness ethylene propylene rubber or rubber (HEPR), Cross-linked polyethylene (XLPE);
- Maximum conductor temperature in normal operation: For PVC/B it is 70 degrees Celsius, for EPR/ HEPR/ XLPE it is 90 degrees Celsius.
- Conductors: shall be class 1 (1 solid conductor) or class 2 (braided conductor) of metallized annealed copper with aluminum/aluminum alloy in accordance with IEC 60228.
- Specifies the nominal thickness of insulation layers PVC/B, XLPE, EPR/HEPR;
- Specifications for three-core cable assemblies, inner sheaths and fillers.
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
Medium Voltage Cables
1-Core Underground Aluminum Cable SUNWON- 12/20 (24) kV-AXSV 1x
Medium Voltage Cables
1-core underground aluminum cable SUNWON- 3.6/6 (7.2) kV-AXSV 1x
Medium Voltage Cables
1-Core Underground Aluminum Cable SUNWON- 6/10 (12) kV-AXSV 1x
Medium Voltage Cables
1-core underground aluminum cable SUNWON- 8.7/15 (17.5) kV-AXSV 1x
Medium Voltage Cables
1-core underground aluminum cable SUNWON-1.8/3 (3.6) kV-AXSV 1x
Medium Voltage Cables
1-core underground aluminum cable SUNWON-18/30 (36) kV-AXSV 1x
Medium Voltage Cables
1-core underground copper cable SUNWON- 1.8/3 (3.6) kV-CXSV 1x
Medium Voltage Cables
1-core underground copper cable SUNWON- 12/20 (24) kV- CXSV 1x
Medium Voltage Cables
1-core underground copper cable SUNWON- 3.6/6 (7.2) kV- CXSV 1x
Medium Voltage Cables
1-core underground copper cable SUNWON- 6/10 (12) kV- CXSV 1x
Medium Voltage Cables
1-core underground copper cable SUNWON- 8.7/15 (17.5) kV- CXSV 1x
Medium Voltage Cables
1-core underground copper cable SUNWON-18/30 (36) kV- CXSV 1x